Services · Lifecycle Engineering
End-to-end elevator lifecycle services across Pakistan.
Design → install → modernize → maintain. One accountable engineering firm from concept to lifetime support, benchmarked to EN 81-20/50.
Design & Engineering
Traffic analysis, shaft-fit calculations and PEC-signed drawings before a single rail is set.
- Traffic study (5-min up-peak handling capacity, HC-5, interval)
- Shaft-fit calculation pack per EN 81-50
- BIM LOD 350 model + shop drawings
- Electrical single-line and load schedule
- PEC-registered engineer sign-off
Installation
Certified crews, controlled alignment tolerances and third-party load testing at handover.
- Rail plumb ±0.5 mm, DBG ±1 mm
- Machine grouting and torque verification
- Insulation & earth-continuity test
- 125% static + 110% dynamic load test
- As-built drawings and O&M dossier
Modernization
Controller, drive, door and cabin retrofits at 40–60% of the cost of full replacement.
- Legacy audit (mechanical + electrical)
- Monarch NICE 3000+ / Fuji Drive retrofit
- Door operator + cabin refresh
- EN 81-20/50 recertification package
- Handover load-test + energy baseline
Preventive Maintenance (AMC)
Monthly 42-point preventive visits, genuine parts and quarterly ride-quality reporting.
- Monthly PPM visits with signed checklist
- Rope, sheave & brake inspection (EN 12385-5)
- ARD activation + battery-health test
- Quarterly A95 vibration & fault-log report
- Genuine OEM parts and warranty retention
24/7 Emergency Support
60-minute entrapment response in Karachi, Lahore and Islamabad under AMC.
- 60-min entrapment SLA in Karachi/Lahore/Islamabad
- 4-hour non-entrapment breakdown SLA
- Remote fault-code retrieval before dispatch
- 24/7 Karachi Network Operations Centre
- Escalation matrix and monthly incident report
IoT Monitoring & Analytics
Real-time telemetry, remote fault logs and predictive maintenance dashboards.
- Trip count, motor current, brake ops telemetry
- Door-cycle and re-open trend analysis
- Ride-quality vibration (ISO 18738-1)
- Predictive alerts on brake, drive, door
- Web dashboard + mobile push alerts
From survey to lifetime support.
Every Liftech project follows the same six-stage process — no ad-hoc handoffs, no missing certificates at commissioning.
- 01
Site Survey
Hoistway measurement, existing-controller audit, building power measurement and traffic profiling.
- 02
Engineering
Rail, buffer and traction calculations to EN 81-50; BIM shop drawings; BMS/fire interface schedule.
- 03
Manufacturing
Cabin fabrication in-country, imported package (machine, controller, doors) with factory test certificates.
- 04
Installation
Certified crew, lifting-plan safety, alignment tolerances, wiring, adjustment and factory acceptance test.
- 05
Commissioning
125% static and 110% dynamic load test, ARD activation, brake torque, no-load and full-load ride-quality run.
- 06
Handover & AMC
Compliance dossier, PEC sign-off, operator training, and roll-over into monthly preventive maintenance.
42-point monthly preventive checklist
Every AMC visit follows the same checklist against EN 81-20/50 and EN 12385-5. A signed copy is filed at the building and uploaded to the Liftech portal.