Parts · PRT-02
Elevator Doors
Landing and car door sets — centre-opening, side-opening and telescopic, with E120 fire ratings.
In short
An elevator door set has two halves: the car door that travels with the cabin and the landing door at every floor. The car door operator drives the landing door through a coupler (skate/vane), and the landing door interlock must be proven closed and locked before the lift can move — this is the single most safety-critical circuit in the installation.
Engineering overview
Doors cause the majority of lift breakdown callouts, so Liftech Global specifies the complete door set as one engineered package: landing door panels and headers, car door panels, VVVF door operator, door lock (interlock), sill, gibs, closer weight or spring, and the light curtain.
Panels are 1.2–1.5 mm steel with SUS 304 hairline, mirror or powder-coated finish. Fire-rated landing doors are tested to EN 81-58 for E60 or E120 integrity, with intumescent seals and steel-wool infill; a fire-rated door must never be mixed with a non-rated header or sill because the certificate covers the assembly, not the leaf.
Door operators are closed-loop VVVF with encoder feedback, giving programmable opening and closing speed, nudging force and reversal sensitivity. EN 81-20 caps closing kinetic energy at 10 J and static closing force at 150 N — Liftech measures and records both on every commissioning sheet.
Types & variants
Centre-opening 2-panel (CO2)
Fastest passenger throughput for 700–1000 mm clear opening; standard for offices and hotels.
Two-speed side-opening (2S)
Maximises clear opening in a narrow shaft — used for hospital, freight and retrofit shafts.
Centre-opening 4-panel (CO4)
Wide 1 400–2 000 mm openings for bed lifts and car/vehicle lifts.
Telescopic 3-panel side-opening (3S)
Where the shaft width is short but a 900–1 100 mm opening is required.
Glass / semi-glass doors
Laminated safety glass leaves for panoramic and showroom lifts, framed in stainless.
Manual swing / collapsible
Goods and dumbwaiter applications where automatic operation is not required.
Technical specifications
| Clear opening width | 700 – 2 000 mm |
|---|---|
| Clear opening height | 2 000 / 2 100 / 2 200 mm |
| Panel material | 1.2–1.5 mm steel, SUS 304 or powder coated |
| Fire rating | EN 81-58 E60 / E120 integrity |
| Operator | VVVF closed loop with encoder, 24/110 V DC |
| Closing kinetic energy | ≤ 10 J (≤ 4 J in nudging) |
| Static closing force | ≤ 150 N |
| Protection | Infra-red light curtain, 154 beams typical |
| Sill | Extruded aluminium or stainless, 3–6 mm car/landing gap |
Gallery
Where it is used
- Commercial towers and hotels (CO2)
- Hospitals and bed lifts (CO4, 2S)
- Narrow retrofit shafts (2S, 3S)
- Fire-protected escape lobbies (E120)
- Panoramic and showroom lifts (glass)
Frequently asked questions
Need elevator doors in Karachi, Lahore or Islamabad?
Send us the model, rail profile or car dimensions and our engineers will confirm compatibility, lead time and pricing.